CD40 error is a Waste Toner Container/box full error.
To reset such an error, you will have to go to diagnostics or service mode as described in a previous blog.
Enter the FS Menu
Go to 08 SETTING MODE, then click “Next”, then click “Classic” on the right top corner.
Type 4541 then press the START (Green) BUTTON. On display will appear two times number 1.
Press number 0 then START.
NOTE: On older Toshiba copiers, you will have to replace the container and restart the printer. If unsuccessful, a tech may repair the copier.